Transparency

COA Vault

Lot-specific source reports, measured results, pending tests and release status.

What a published lot record means

Each record links a product and package to its lot, laboratory and source report. The six-area peptide testing programme is distinct from the tests completed for that lot. A release based on HPLC purity and content can have additional tests pending. Measured results, VERIPHASE acceptance criteria and release status are separate information; publication is not a claim that every test passed.

1 / 11 public lots shown
Compound / Lot Measured result Status Report
CJC-1295 No-DAC + Ipamorelin5+5mg
Lot 26-0042VP-CJC-IPA-55 · current
HPLC purity
CJC-1295 no DAC: 99%; Ipamorelin: 99%
Measured peptide content: CJC-1295 No-DAC
4.50 mg
Measured peptide content: Ipamorelin
5.25 mg
Reported
Additional lot evidence
Measured peptide content: CJC-1295 No-DAC
4.50 mgHPLC; original report 100019714, pages 1-2
Measured peptide content: Ipamorelin
5.25 mgHPLC; original report 100019714, pages 1-2
Released Additional tests pending
View pending tests
  • MS identity — Pending
  • Endotoxin — Pending
  • Elemental impurities — Pending
  • Bioburden — Pending
  • Sterility — Pending

HPLC purity and content are reported for this lot. Additional tests remain pending; this is not a complete test panel.

Open COA · PDF ↗
Analiza Bialek sp. z o.o.Report date:
Report details

Source ref: Analiza order 100019714; report UIWE9XON; sample lot 26-0042